Tech Notes


The Benefits of OOP in PLC Programming: A Case Study With a Conveyor System

In this blog post, we’re diving into object-oriented programming (OOP) in PLC programming. First, we’ll introduce the basics of OOP — including how it differs from traditional procedural programming in programmable logic controllers (PLC).

Read More


CODESYS Tutorial: How To Get the Actual Cycle Time of a Current Task

Exploring the importance of task cycle time monitoring in control systems to improve efficiency, detect bottlenecks and enhance system stability.

Read More


Reading and Writing IO-Link Parameters on a CPX-E on a Rockwell PLC through EtherNet/IP

IO-Link is the first standardized IO technology worldwide (IEC 61131-9) for communication with devices such as pressure sensors, electric actuators, RFID readers, light stacks, temperature sensors and many others.

Read More


CMMT-AS/EMMB-AS-xx-xx-K-S30Mx Battery Errors: ‘Protocol error Nikon-A encoder’ and ‘Encoder Type Plate Invalid’

When selecting a multi-turn encoder on the EMMB-AS motor series, you are required to purchase an encoder cable adapter (highlighted in gray below) in addition to the motor and encoder cables that include a battery holder.

Read More


Application Notes Siemens TIA Portal / Festo CPX-MPA Commissioning

The purpose of this post is to provide a workflow and instructions needed to commission CPX-MPA with Profinet and Siemens S7-1200 PLC. This document applies to TIA Portal V13 SP1. These instructions include two methods of configuration: manual and auto-scan technique.

Read More


Quick Start Guide Siemens TIA Portal / Festo CPX-FB34/44 Commissioning

The purpose of this post is to provide a workflow and instructions needed to commission CPX-FB34/44 with Siemens, S7-1200 Series Modular PLC. This document applies to TIA Portal V16 Update 4. These instructions include manual configuration of Siemens and Festo hardware components.

Read More


Quick Start Guide Siemens TIA Portal / Festo CPX Diagnostics

The purpose of this post is to provide instructions and a sample project needed to understand the diagnostics information of CPX with Siemens, S7-1200 Series Modular PLC. This document applies to TIA Portal V16 Update 4.

Read More


Setting up CMMT using Point to Point, EtherCAT version, using CODESYS Soft PLC

Explore a comprehensive guide on setting up CMMT using Point to Point, EtherCAT version with CODESYS Soft PLC. From project creation to device configuration, this blog post provides detailed instructions and valuable insights to streamline your setup process.

Read More


First Steps with PLC (CPX-E-CEC), Servo (CMMT) and HMI (CDPX)

In this blog post Bryan Moloney, an Application Engineer at Festo USA, takes you through the essential hardware and software components required for setting up a comprehensive automation system.

Read More


CPX-AP-x-4IOL-M12: Working with OE variants in EtherNet/IP

When using a CPX-AP-x-4IOL-M12 module on an EtherNet/IP network, it is recommended to use the non-OE Variant for selecting the port size. This way, you won’t have to deal with OutputEnable.

Read More

About Festo

For over 50 years in the US and almost 100 years globally, Festo has been a positive force for manufacturers. Our passion is automation — intelligent automation solutions that transform the way people work — and the way companies compete. Ultimately, it’s about continuously stimulating progress. In big ways and in small ways.